CONTROL UNIT – MPC
Design – plus
Operating Temperature – -20 °C to +70 °C
Water Resistance – 4g (2…100Hz) – IEC 60068-2-6, test Fc
Weight – 2.4kg
Operating voltage – 24 V DC – 25 % / + 30 % or 12 V DC – 20 % / + 30 %
Operation current – 24V DC: 3 A max., 12V DC: 6 A max.
Protection – With screw cable gland: IP 54 acc. to IEC 60529 (DIN VDE 0470)
Fuse – 10 A (T)
The MPC is the central processing unit of the remote control. They is also responsable for data in- and output.
Type Numbers
For application |
Type number |
Reversing gear propulsion system |
346 069 003 0 |
*standard for mechanical gear or speed setting
** for mechanical pitch setting where the propeller can be shifted to sailing position
None.
Device |
MPC – plug no. |
Length |
Type number |
---|---|---|---|
Cable for prop-vale and gear setting / feed back signal |
4, 5 |
2 m |
894 620 279 2 |
5 m |
894 620 271 2 |
||
10 m |
894 620 270 2 |
||
15 m |
894 620 272 2 |
||
Cable for rpm setting / feed back signal and trolling setting |
6, 7 |
2 m |
892 620 229 2 |
5 m |
892 620 221 2 |
||
10 m |
892 620 220 2 |
||
15 m |
892 620 222 2 |
||
Actuator for mechanical trolling |
3 |
323 698 000 0 |
|
Actuator for mechanical speed or gear setting* |
7 |
323 698 100 0 |
* see page of actuator 323 698 100 0 for power supply and signal cable of actuator
Device |
Description |
Type number |
Fuse |
Fuse 10 A |
894 245 201 4 |
Repair / replace |
Only repair or complete changing of device possible* |
– |
* Software version and adjusted parameters (parameter list) are needed to repair or replace the MPC