main_sm
dia

CONTROL UNIT – MPC

Design – plus
Operating Temperature – -20 °C to +70 °C
Water Resistance – 4g (2…100Hz) – IEC 60068-2-6, test Fc
Weight – 2.4kg
Operating voltage – 24 V DC – 25 % / + 30 % or 12 V DC – 20 % / + 30 %
Operation current – 24V DC: 3 A max., 12V DC: 6 A max.
Protection – With screw cable gland: IP 54 acc. to IEC 60529 (DIN VDE 0470)
Fuse – 10 A (T)

The MPC is the central processing unit of the remote control. They is also responsable for data in- and output.

Type Numbers

For application

Type number

Reversing gear propulsion system

346 069 003 0

*standard for mechanical gear or speed setting
** for mechanical pitch setting where the propeller can be shifted to sailing position

Description

None.

 

Device

MPC – plug no.

Length

Type number

Cable for prop-vale and gear setting / feed back signal

4, 5

2 m

894 620 279 2

5 m

894 620 271 2

10 m

894 620 270 2

15 m

894 620 272 2

Cable for rpm setting / feed back signal and trolling setting

6, 7

2 m

892 620 229 2

5 m

892 620 221 2

10 m

892 620 220 2

15 m

892 620 222 2

Actuator for mechanical trolling

3

323 698 000 0

Actuator for mechanical speed or gear setting*

7

323 698 100 0

* see page of actuator 323 698 100 0 for power supply and signal cable of actuator

 

Device

Description

Type number

Fuse

Fuse 10 A

894 245 201 4

Repair / replace

Only repair or complete changing of device possible*

* Software version and adjusted parameters (parameter list) are needed to repair or replace the MPC