Description
Mounting Hole Pattern
Refer to Turbine Series introduction page for filter dimensions

Performance Graphs
These results are from controlled laboratory tests. Field results may vary by application.
 |
|
Item
|
Part No.
|
Description
|
Case Qty.
|
|
1
|
RK11888
|
T-handle
|
1
|
|
11350
|
T-handle O-ring
|
10
|
|
2
|
RK15078
|
Lid
|
1
|
|
3
|
15005
|
Lid Gasket
|
10
|
|
4
|
RK15377-01
|
Body, 3/4″-16 UNF Ports (MA, effective 1/15/96)
|
1
|
|
RK15082
|
Bodv. 9/16″-18 UNF Ports (prior to 1/15/96)
|
1
|
|
5
|
RK15090
|
Mountinn Bracket. unitized with Bowl Ring (MA)
|
1
|
|
6
|
15374
|
Bowl Gasket (supercedes 15009 0-ring-All models)
|
10
|
|
7
|
RK15013D
|
Turbine Centrifuge/Conical Baffle
|
1
|
|
8
|
RK15279-01
|
See-thru Bowl w/Water Probe Plug, (MA)
|
1
|
|
RK15301-01
|
Metal Bowl w/1/4″ NPT Drain & Water Probe Port
|
1
|
|
9
|
RK151041
|
Heat Deflector Shield (MA)
|
1
|
|
10
|
RK210692
|
Water Probe Assembly
|
1
|
|
11
|
RK20022
|
Metal Water Probe Port Plug
|
1
|
|
12
|
11340
|
Drain Fitting O-ring (New Style)
|
1
|
|
13
|
11041
|
Bowl Drain Washer (New and Old Style)
|
10
|
|
14
|
RK19492
|
Diesel Marine Shut-off Valve Kit
|
1
|
|
15
|
RK15300
|
Mounting Bracket, 3-piece (MAM)
|
1
|
|
16
|
918-N4
|
Bowl plug 1/4″ NPT (Old and New Style)
|
1
|
|
17
|
11-1910
|
Bowl Drain Fitting (New Style)
|
1
|
|
RK11-1910
|
Complete Bowl Drain Fitting Kit (New Style)
|
1
|
|
11040
|
Bowl Drain Fitting (Old Style)
|
10
|
|
18
|
RK15010B
|
Check Ball w/Seal
|
1
|
|
19
|
RK15081-013
|
Phillips Head Cap screws 10-24×1″ (4)
|
1
|
|
RK150813
|
Hex/Washer Head Cap screws 10-24×7/8″ (4)
|
1
|
|
20
|
2010SM-OR2
|
Micron Element w/Seals
|
12
|
|
201OTM-OR10
|
Micron Element w/Seals
|
12
|
|
201OPM-OR30
|
Micron Element w/Seals
|
12
|
|
21
|
RK15079
|
Return Tube (w/tapered pipe base threads)
|
1
|
|
22
|
RK15211
|
Seal Service Kit (all models – not shown)
|
1
|
|
15335
|
Installation Instructions, 500MA
|
|
1 For diesel service only. Must be used with a Water Detection Kit.
2 For replacement only. The Coast Guard does not accept “FG” units converted to “MA” configurations.
3 Units built prior to Fall, 1998 |
Replacement Service Elements
For all Model 500 Series
SERVICE ELEMENT INCLUDES LID SEAL AND T–HANDLE O–RING.
2010SM-OR 2 Micron (Brown end caps)
Recommended for Final/Secondary Filtration
2010TM-OR 10 Micron (Blue end caps)
Recommended for Primary or Secondary Filtration
2010PM-OR 30 Micron (Red end caps)
Recommended for Primary Filtration* Only.